Step 6 If the server is turned off, turn on the server.
Step 7 Make sure that the ac and dc power LED on the power supply is lit, indicating that the power
supply is operating correctly.
----End
Removing a QPI wrap card
To remove a QPI wrap card from the server, complete the following steps.
Step 1 Read the safety information and "Installation guidelines".
Step 2 Turn off the server and peripheral devices, and disconnect the power cords and all external
cables as necessary.
Step 3 Rotate the blue release latch on the handle and pull the handle to the open position.
Step 4 Slide the wrap card out of the server.
Step 5 If you are instructed to return the wrap card, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
----End
Replacing a QPI wrap card
To install the replacement QPI wrap card, complete the following steps:
Step 1 Rotate the blue release latch on the handle and pull the handle to the open position.
Step 2 Push the wrap card into the bay, and slide the handle to the locked position.
Step 3 Connect the cables and power cords (see "Connecting the cables" for cabling instructions).
Step 4 Turn on all attached devices and the server.