Message
Sensor
Sys
Board
has
transitioned to critical
from a less severe state.
Power Messages
Redundancy Lost for Power
Group 1 has asserted.
Redundancy Power Group 1 has
been restored.
Failure predicted on EPOW Fault Error
Failure no longer predicted on
EPOW Fault
Power Supply n has failed.
(n = power supply number)
Issue 02 (2011-05-25)
Severity Description
Fault
Error
A sensor has changed to Critical
state from a less severe state.
Error
One power supply has lost AC.
Power is no longer redundant.
Info
Redundancy has been restored.
AC power lost to a power supply. Make sure there is enough power
Info
EPOW fault recovered
Error
Power supply n has failed
(n = power supply number)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Diagnostics
Action
1.
Check the system-event
log.
2.
Check for an error LED on
the I/O board.
3.
Replace any failing device.
4.
Check for a server
firmware update.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
5.
(Trained service technician
only) Replace the I/O board.
Install another power supply to
acquire redundancy.
No action; information only.
supplied to the server.
No action; information only.
1.
If the power-on LED is lit,
complete the following steps:
a.
Reduce the server to the
minimum configuration.
b.
Reinstall the components
one at a time, restarting the
server each time.
c.
If the error recurs, replace
the component that you just
reinstalled.
2.
Reseat power supply n.
3.
Replace power supply n. (n
= power supply number)
3-75