6 Configuration information and instructions
6-4
Select this choice to view or change power settings.
Active Energy Manager
Select this choice to enable or disable power capping. If you enable power capping,
the Active Energy Manager program will limit the maximum power that is consumed
by the server.
Power Restore Policy
Select this choice to determine the mode of operation to which the server will be
restored after a power outage occurs. You can select Always on, Always off, or
Restore to restore the server the state it was in at the time of the power outage.
Operating Modes
Select this choice to select the memory speed or to specify a preset operating mode to
configure the server for maximum power savings, maximum efficiency, or maximum
performance.
- Efficiency mode
Select this choice to maintain the optimal balance between performance and power
consumption. The server generally produces the best performance per watt while it is
in this mode.
- Acoustic mode
Select this choice to configure the server to draw the minimum amount of power and
generate the least noise. Server performance might be degraded depending on the
application that you are running.
- Performance mode
Select this choice to achieve the highest absolute performance for most server
applications. The power consumption in this mode is often higher than in the
Efficiency or the Acoustics mode.
- Custom mode
Select this choice only if you understand the functions of the low-level IMM settings.
This is the only choice that enables you to change the low-level IMM settings that
affect the performance and power consumption of the server.
Integrated Management Module
Select this choice to view or change the settings for the integrated management
module.
- POST Watchdog Timer
Select this choice to view or enable the POST watchdog timer.
- POST Watchdog Timer Value
Select this choice to view or set the POST loader watchdog timer value.
- Reboot System on NMI
Enable or disable restarting the server whenever a nonmaskable interrupt
(NMI) occurs. Disabled is the default.
- Commands on USB Interface Preference
Enable or disable the Ethernet over USB interface on IMM.
- Network Configuration
Select this choice to view and select the system management network interface port,
the IMM MAC address, the current IMM IP address, and host name; define the static
IMM IP address, subnet mask, and gateway