3 Diagnostics
0058008
00580A1
00580A4
00580A5
0068002
2011000
3-26
DIMM failed memory test
Invalid DIMM population
for mirroring mode
Memory population changed
Mirror failover complete
CMOS battery cleared
PCI-X PERR
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Problem Determination and Service Guide
2. Remove the lowest-numbered DIMM pair of
those that are identified, replace it with an
identical pair of known good DIMMs, and then
restart the
server. Repeat as necessary. If the failures
continue, go to step 4.
3. Return the removed DIMMs, one pair at a
time, to their original connectors, restarting the
server after each pair, until a pair fails. Replace
the DIMMs in the failed pair with identical
known good DIMMs, restarting the server after
each DIMM is installed. Replace the failed
DIMM. Repeat this step until you have tested
all removed DIMMs.
4. Replace the memory card.
1. Reseat the DIMMs, and then restart the
server.
2. Replace the following components one at a
time,
in the order shown, restarting the server each
time:
a. DIMMs
b. Memory card
1. If a fault LED is lit, resolve the failure.
2. Install the memory cards and DIMMs in the
correct sequence (see "Memory cards and
memory modules (DIMM)").
Information only. Memory has been added,
moved, or changed.
Information only. Memory redundancy has
been lost.Check the event log for uncorrected
DIMM failure events.
1. Reseat the battery.
2. Clear the CMOS memory (see "I/O-board
jumpers").
3. Replace the following components one at a
time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) I/O board
1. Check the I/O-board LEDs.
2. Reseat all affected adapters.
3. Update the PCI device firmware.
4. Remove the adapters from the I/O board.