Huawei Tecal RH5485 Problem Determination And Service Manual page 110

Hide thumbs Also See for Tecal RH5485:
Table of Contents

Advertisement

3 Diagnostics
Message
The connector QPI
Interconnect has encountered
a configuration error.
The
connector
Detect
has encountered a
configuration error.
Recovery Messages
Rebuild in process for
Array in sys- tem SN#
ZZZZZZP
The Drive n Status has
been enabled.
The Drive n Status has
been added.
Memory Device n disabled
on sub- system System
Memory.
DIMM Err Card n
disabled on sub- system
System Memory.
One of DIMMs disabled
on subsys- tem System
Memory.
All DIMMs disabled on
subsystem
System Memory.
Watchdog Timer expired for
Watch- dog.
Power Supply n has been
removed from container
Chassis 1.
3-92
Severity Description
Error
USB
Error
Info
Info
Info
Info
Info
Info
Info
Info
Info
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
The system had detected an
internal connection error.
A USB cable is disconnected.
The storage subsystem is in a
recovery state.
The storage subsystem is in a
recovery state.
The storage subsystem is in a
recovery state.
-
-
-
-
-
-
Tecal RH5485 Server
Problem Determination and Service Guide
Action
1.
Reseat the QPI wrap card, if
installed.
2.
Reseat any installed QPI
cables.
3.
(Trained service technician
only) Replace the microprocessor
board.
1. Make sure that all the USB
cables are connected and that
there is no damage to the
connectors.
2. Check the internal cable from
the I/O board to the system
front panel.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
Issue 02 (2011-05-25)

Advertisement

Table of Contents
loading