Problem Determination and Service Guide
Message
Processor n has failed
with FRB1/ BIST (built-in
self-test) condition. (n =
microprocessor number)
Processor n has recovered
from a
Configuration Mismatch. (n =
microprocessor number)
Issue 02 (2011-05-25)
Severity Description
Error
A processor failed - FRB1/BIST
Error
A processor configuration
mismatch has occurred.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Diagnostics
Action
1.
Check for a server
firmware update.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
2.
Make sure that the installed
microprocessors are compatible
with each other
(see"Microprocessor" for
information about
microprocessor requirements).
3.
(Trained service technician
only) Reseat microprocessor n.
4.
(Trained service technician
only) Replace microprocessor n.
(n = microprocessor number)
1.
Make sure that the installed
microprocessors are compatible
with each other (see
"Microprocessor" for
information about
microprocessor requirements).
2.
(Trained service technician
only) Replace the incompatible
microprocessor.
3-69