Tecal RH5485 Server
Problem Determination and Service Guide
Message
Sensor
PS n
12V
Fault
has
transitioned to
non-critical from a nor- mal
state.
(n = power supply number)
Sensor
PS n
12V
Fault
has
transitioned to
non-critical from a nor- mal
state.
Sensor
PS n
12V
Fault
has
transitioned to
non-critical from a nor- mal
state..
(n = power supply number)
Sensor
PS
n
Fault
has
transitioned to
a non-critical state from
a normal state.
(n = power supply number)
Issue 02 (2011-05-25)
Severity Description
OV
Warning A sensor has changed
UV
Warning A sensor has changed
OC
Warning A sensor has changed
CSF
Warning A sensor has changed
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
tonon-critical state from a normal
state
tonon-critical state from a normal
state
tonon-critical state from a normal
state
tonon-critical state from a normal
state
3 Diagnostics
Action
1.
Check the OVER SPEC
LED (see the information about
the OVER SPEC LED in "Light
path diagnostics LEDs").
2.
Remove the power
supplies.
3.
Replace power supply n.
4.
(Trained service technician
only) Replace the I/O-board
shuttle.
(n = power supply number)
1. Check the OVER SPEC
LED (see the information about
the OVER SPEC LED in "Light
path diagnostics LEDs").
2. Remove the power supplies.
3. Replace power supply n.
4. (Trained service technician
only) Replace the I/O-board
shuttle.
(n = power supply number)
1.
Check the OVER SPEC
LED (see the information about
the OVER SPEC LED in "Light
path diagnostics LEDs" ).
2.
Remove the power
supplies.
3.
Replace power supply n.
4.
(Trained service technician
only) Replace the I/O-board
shuttle.
(n = power supply number)
1. Check the power supply n
LEDs.
2. Replace the failing power
supply.
(n = power supply number)
3-79

Advertisement

Table of Contents