Message
A diagnostic interrupt has
occurred on system %1.
(%1 =
CIM_ComputerSystem.
ElementName)
A bus timeout has
occurred on sys- tem %1.
(%1 = CIM_ComputerSystem
.ElementName)
A software NMI has
occurred on sys- tem %1.
(%1 = CIM_ComputerSystem
.ElementName)
The System %1 encountered
a POST Error.
(%1 = CIM_ComputerSystem
.ElementName)
3-72
Severity Description
Error
An operator information panel
NMI/diagnostic interrupt has
occurred
Error
A bus timeout has occurred.
Error
A software NMI has occurred.
A POST error has occurred.
Error
(Sensor = ABR Status)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Tecal RH5485 Server
Problem Determination and Service Guide
Action
If the NMI button on the operator
information panel has not been
pressed, complete the following
steps:
1. Make sure that the NMI
button is not pressed.
2. Replace the operator
information panel cable.
3. Replace the operator
information panel.
1. Remove the adapter from the
PCI slot that is indicated by a lit
LED.
2. Replace the adapter.
3. Remove all PCI adapters.
4. (Trained service technicians
only) Replace the I/O board.
1.
Check the device driver.
2.
Reinstall the device driver.
1.
Recover the server
firmware from the backup page
(see "Recovering the server
firmware").
2.
Update the server firmware
to the latest level.
Important:
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update the code
Issue 02 (2011-05-25)