Problem Determination and Service Guide
The following table describes the problems that are indicated by various combinations of the
power-supply LEDs and the power-on LED on the operator information panel and suggested
actions to correct the detected problems.
Figure 2-7 Power-supply LEDs
Power-supply LEDs
AC
Off
Off
Off
Off
Issue 02 (2011-05-25)
Locator LED: Use this LED to visually locate the server among other servers.
In a two-node configuration, this LED is lit on the primary server and flashes on the
secondary server during POST.
You can press this button or use an IPMI command to turn this LED on or off.
System-error LED: When this LED is lit, it indicates that a system error has occurred.
An LED on the light path diagnostics panel is also lit to help isolate the error.
Power-on LED: See "Operator information panel" for the various states of the power-on
LED.
DC
Error
Off
Off
Off
On
On
Off
On
On
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
Action
No ac power to
1. Check the ac power to the
either
power
server.
supply
or
a
2. Make sure that the power
problem
with
cord
the ac power
functioning power source.
source
3. Turn the server off and then
turn the server back on.
4. If the problem remains,
replace the power supply.
No ac power to
1. Replace the power supply.
the server or a
2. Make sure that the power
problem
with
cord
the ac power
functioning powersource.
source and the
power
supply
had detected an
internal
problem
Faulty
power
Replace the power supply.
supply
Faulty
power
Replace the power supply.
supply
is
connected
to
is
connected
to
2 Introduction
Notes
This
is
a
normal
condition
when no ac
a
power
is
present.
This happens
only when a
second
a
power
supply
is
providing
power to the
server.
-
-
2-9

Advertisement

Table of Contents
loading

Table of Contents