Power Fail Transfer Unit - Nortel 1000 Installation And Commissioning Manual

Table of Contents

Advertisement

Installing and cross-connecting a

Power Fail Transfer Unit

Contents
Introduction
This section contains information on the following topics:
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing and connecting a QUA6 PFTU . . . . . . . . . . . . . . . . . . . . . . .
Installing and connecting a third-party PFTU. . . . . . . . . . . . . . . . . . . .
Connecting an analog (500/2500-type) telephone to a PFTU. . . . . . . .
Connecting a trunk to a PFTU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power fail transfer occurs when the main power to the CS 1000E system is
cut off. When a power interruption occurs, the Power Fail Transfer Unit
(PFTU) connects predetermined analog (500/2500-type) telephones directly
to the Central Office trunks. A PFTU is capable of supporting a maximum of
five or eight telephones (depending on the PFTU type).
A PFTU can be connected to the AUX connector on a Media Gateway.
A PFTU does not support Digital trunks. Use Analog trunks if power
failure backup is required.
Communication Server 1000E
IMPORTANT!
Installation and Commissioning
Page 437 of 466
437
438
443
444
448

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000eCommunication server 1000Communication server 1000e

Table of Contents