Nortel 1000 Installation And Commissioning Manual page 57

Table of Contents

Advertisement

Figure 7
Connectors at the back of the ISP1100 Signaling Server
not used
Universal AC
power cord
connector
CP PM Signaling Server
not used
not used
The CP PM Signaling Server is in the form of a circuit card and comes in two
distinct models, NTDW61 and NTDW66. The NTDW61 model is designed
for use in a CS 1000E system and the NTDW66 model is designed for use in
a CS 1000M system.
There are several switches on CP PM circuit cards. All switch settings
must be factory defaults except for the switch labelled "S5". Switch S5
must be set to position 2 to support the internal hard drive used on the
CP PM Signaling Server circuit cards only.
Installation in a CS 1000E system
The NTDW61 model of the CP PM Signaling Server circuit card can be
inserted into any slot of an IPMG (MG 1000E or MG 1000B) or 11C cabinet
in a CS 1000E system, except slot 0. Slot 0 is reserved for an SSC or an MGC.
Communication Server 1000E
System components
TLAN (P2)
ELAN (P1)
IMPORTANT!
Page 57 of 466
Maintenance/
Admin port
Installation and Commissioning