Configuring The Fiber Remote Multi-Ipe Interface Unit - Nortel Communication Server 1000 Series Manual

Fiber remote multi-ipe interface fundamentals
Table of Contents

Advertisement

To remove the configuration of the Remote IPE superloop, load
Maintenance and Diagnostic Program LD 32 and execute the DISL sl
command to disable the superloop. Then, load Configuration Record
Program LD 97 to delete the configuration records of the superloop for the
Superloop Network card and the Peripheral Controller card.
To check the status of the specified superloop, load the LD 32 and execute
the STAT sl, where sl is the superloop number.
Configuring the Fiber Remote Multi-IPE Interface unit
The configuration and administration of the Fiber Remote Multi-IPE
Interface at the local or the remote site consists of the following:
Copyright © 2007-2009 Nortel Networks
.

Configuring the Fiber Remote Multi-IPE Interface unit 93

Table 23
To delete the configuration record for the superloop
Prompt
Response
REQ
CHG
TYPE
SUPL
SUPL
X8
Table 24
To delete the configuration record for the Remote IPE module
REQ
CHG
TYPE
XPE
XPEC
X2
selecting the MMI terminal modes
setting modem parameters
configuring fiber-optic link performance criteria
performing maintenance functions
conducting test and diagnostic functions
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Description
Deleting the Superloop Network card
configuration record
Superloop
Remove record for superloop number 8
Change configuration record
Remote IPE
Delete configuration record for the Peripheral
Controller 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000e cp piiCommunication server 1000e cp pivCommunication server 1000e cp pmCommunication server 1000m single group cp piiCommunication server 1000m single group cp pivCommunication server 1000m multi group cp pii ... Show all

Table of Contents