Table 21
Customer made cable pin out (same as NTDU6302)
Pins on DB9 Female
1
6
2
3
4
5
7
NN43041-310
Standard 01.11
Connecting an MRV LX8020S-102AC-R Terminal Server
Follow Procedure 59 to connect a Terminal Server with a CS 1000E system.
Table 20 lists the MRV cables required to install the LX8020S-102AC-R
Terminal Server in a CS 1000E system.
Table 20
Required MRV serial cables and connectors
Order Code
NTDU6302
NTDU6303
P/N-151-3028
P/N-350-0308
Customer-made cables with the following pin out can also be used. See Table
21.
DCD
DSR
RXD
TXD
DTR
S GND
RTS
October 2008
Description
Connects MRV Terminal Server to any standard
DTE port or DCE port when a Null modem is
used
Used for telnet, rlogin connections
Male RJ-45 to Male RJ-45 with connectors,
10 feet
Female RJ-45 to Female DB9
Pins on RJ-45 Male (MRV Terminal Server)
2
3
6
7
4
5
1
DTR
TxD
RxD
DSR/DCD
TxD GND
RxD GND
CTS