Nortel 1000 Installation And Commissioning Manual page 283

Table of Contents

Advertisement

Controlling the baud rate
Table 23
SDI port numbering
Port
Use
0
MTC/SCH/BUG
1
MTC/SCH/BUG
2
MTC/SCH/BUG
Configuring a terminal and SDI ports
SDI2 is not available during the MGC bootup, it cannot be used to access the
installation menus.
All of the SDI ports on the MGC are configured via software. There are no
DIP switches on the MGC for configuring the baud rate of SDI0.
You can use a switch setting on the SSC's faceplate to control the baud rate
for port 0. Use LD 17 to configure port 1 and port 2. Make sure the baud rate
and device option settings are set correctly.
Use Port 0 for software installation and upgrades. Port 0 is the only
system terminal (SDI) port that you can use for software installation and
upgrades.
You can use all three ports on the SSC to connect terminals or modems.
Use an NTBK48 3-port SDI cable with the SSC.
Table 23 shows the SDI port numbering.
Baud rate
Set by a DIP switch
1200
1200
Communication Server 1000E
Data bits
Stop bits
8
1
8
1
8
1
Installation and Commissioning
Page 283 of 466
Parity
None
None
None