Configuring Virtual Tone And Conference Circuits - Nortel 1000 Installation And Commissioning Manual

Table of Contents

Advertisement

Page 160 of 466

Configuring Virtual Tone and Conference Circuits

LD 17 – Add Virtual Tone and Conference loops.
Prompt
Response
REQ
CHG
TYPE
CEQU
...
...
MGTDS
X
IPMG
a b
MGCONF
X
IPMG
a b
NN43041-310
Standard 01.11
Configuring the CS 1000E CP PM Call Server
TTY 13: DSBL DES: ether 2
TTY 14: DSBL DES: ether 3
3
Enter the command:
****
4
Perform an EDD to save your changes.
Virtual Tone and Conference Circuits must be defined for use by each
MG 1000E. Use LD 17 to add MGTDS and MG Conference loops. The
Virtual Tone and Conference Circuits in the same MG 1000E must occupy
contiguous double loops. For easy management, Nortel recommends to start
the MGTDS and MG Conference loops from a loop number high enough (for
example, 60) to leave enough superloop number for all MG 1000E
superloops.
Comment
Change existing data
Common Equipment
(x=superloop number)
(a=loop of MG, b=shelf of MG)
(x=superloop number)
(a=loop of MG, b=shelf of MG)
October 2008
End of Procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000eCommunication server 1000Communication server 1000e

Table of Contents