Figure 55
Import Node Files – Retrieve and upgrade configuration files
Configuring the CS 1000E CP PM Call Server
1
Select System > IP Network > Nodes: Servers, Media Cards from the
navigator.
The Node Configuration web page appears. No nodes are defined.
2
Import the Node files from the leader Signaling Server.
a.
Click Import Node Files on the Node Configuration web page.
The Import Node Files screen in Figure 55 on
b.
Enter the ELAN IP address of the leader Signaling Server in the input
box.
3
Click Import.
A success message appears.
4
Click OK to go to the next procedure.
Communication Server 1000E
End of Procedure