Page 154 of 466
NN43041-310
Standard 01.11
Configuring the CS 1000E CP PM Call Server
LOCK
<enter to accept default or set to required setting>
FLTA
<enter to accept default or set to required setting>
AUDT
<enter to accept default or set to required setting>
LLID
<enter to accept default or set to required setting>
4
Enter the command:
ACCOUNT_REQ new
5
Enter the command:
PWD_TYPE pwd2 (pwd1, pwd2, lapw are options)
6
Enter the command:
USER_NAME kattest (username)
7
Enter the command:
PASSWORD (userpassword)
8
Enter the command:
CONFIRM (confirm password)
9
Enter the command:
ACCT yes (yes for pdt access, default for no pdt access
10 Enter the command:
PDT pdt2 (pdt1 or pdt2)
11 Enter the command:
ACCOUNT_REQ new
12 Enter the command:
PWD_TYPE lapw
13 Enter the command:
PWTP ovly
14 Enter the command:
USER_NAME kattest (username)
October 2008