Connecting A Trunk - Nortel 1000 Installation And Commissioning Manual

Table of Contents

Advertisement

Page 292 of 466

Connecting a trunk

NN43041-310
Standard 01.11
Installing and cross-connecting a trunk card
NTRB21 TMDI 1.5 Mbit DTI/PRI
NT6D70 SILC
NT6D71 UILC
Note: Now NT6D70 SILC and NT6D71 UILC Digital trunk cards can
be installed in slots 7 to 10 in a Media Gateway Expander.
For additional information about installing Digital trunk cards, refer to the
following documents:
ISDN Primary Rate Interface: Installation and Configuration
(NN43001-301)
ISDN Basic Rate Interface: Installation and Configuration
(NN43001-318)
ISDN Primary Rate Interface: Maintenance (NN43001-717)
ISDN Basic Rate Interface: Maintenance (NN43001-718)
Follow Procedure 66 to connect a trunk.
Procedure 66
Connecting a trunk
1
From the assignment record, determine the location of the trunk
connection and its associated Terminal Number (TN) at the
cross-connect terminal.
2
With cross-connect wire, connect the trunk to the TN.
Make sure that the wiring is not reversed and that it is on the correct
terminals.
Table 24 on
for trunks.
For European trunk connections, see Table 27 on
Table 35 on
For UK trunk connections, see Table 36 on
page
316.
October 2008
page 293
to Table 26 on
page
307.
page 296
list the connections
page 298
page 309
to Table 42 on
to