Installing And Cross-Connecting - Nortel 1000 Installation And Commissioning Manual

Table of Contents

Advertisement

Installing and cross-connecting a Power Fail Transfer Unit
Table 61
Power Fail Transfer Unit connections (Part 1 of 2)
Function
Pair
5T
5R
P
F
6T
6R
T
7T
7R
1
8T
8R
9T
9R
P
F
10T
10R
T
11T
11R
2
12T
12R
13T
13R
P
14T
F
14R
T
15T
15R
3
16T
16R
6
Repeat for each trunk assigned to the PFTU.
Color
Connects to:
W-S
Telephone
S-W
R-BL
Telephone Line card
BL-R
R-O
Central office trunk
O-R
R-G
Trunk Line card
G-R
R-BR
Telephone
BR-R
R-S
Telephone Line card
S-R
BK-BL
Central office trunk
BL-BK
BK-O
Trunk Line card
O-BK
BK-G
Telephone
G-BK
BK-BR
Telephone Line card
BR-BK
BK-S
Central office trunk
S-BK
Y-BL
Trunk Line card
BL-Y
Communication Server 1000E
QUA6 J1 cable
Page 449 of 466
Connects to:
TN assigned to the telephone
TN assigned to the Trunk
TN assigned to the telephone
TN assigned to the Trunk
TN assigned to the telephone
TN assigned to the Trunk
Installation and Commissioning

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000eCommunication server 1000Communication server 1000e

Table of Contents