Connecting An Attendant Console; Procedure 92: "Connecting An Attendant Console - Nortel 1000 Installation And Commissioning Manual

Table of Contents

Advertisement

Connecting an attendant console

Installing Line cards and cross-connecting telephones
Figure 171
NTAK92BA Off-Premise Protection Module connections
NTAK92AA
Off-Premise
Protection
Module
Ground lug
Connector J2
NTAK9204
Cable
Procedure 92
Connecting an attendant console
1
Locate the attendant console terminations at the cross-connect terminal.
2
Locate the Line card terminations at the cross-connect terminal.
3
With cross-connect wire, connect the Line card and other connections to
the console, as shown in Figure 172 on
Communication Server 1000E
Connector J1
End of Procedure
Page 387 of 466
Cross-connect
terminal block
T1
BL - 1W
R1
BL - 2W
T2
O - 1W
J2
R2
O - 2W
T3
G - 1W
R3
G - 2W
T4
BR - 1W
R4
BR - 2W
T1
BL - 1W
R1
BL - 2W
T2
O - 1W
J1
R2
O - 2W
T3
G - 1W
R3
G - 2W
T4
BR - 1W
R4
BR - 2W
NTAK9204
Cable
page
388.
Installation and Commissioning
To off-premise
telephones
To analogue
line card in
Option 11
cabinet
553-8351.EPS