Nortel 1000 Installation And Commissioning Manual page 259

Table of Contents

Advertisement

Connecting an IR-8020M-101 Terminal Server
Where:
xx = port number
2
Enable a dedicated service using rlogin. Enter the command:
DEFINE PORT XX RLOGIN DEDICATED SERVICE xx.xx.xx.xx
Where:
xx = port number
xx.xx.xx.xx = port IP address
3
Enable the port to be accessible only by local command and from a serial
connection only. Enter the command:
DEFINE PORT xx ACCESS LOCAL
Where:
xx = port number
4
Enable the In-Reach Element Manager to complete a ZMODEM transfer
using the rlogin feature. Enter the command:
DEFINE PORT xx RLOGIN TRANSPARENT MODE ENABLED
Where:
xx = port number
Note 1: When the rlogin transparent mode is enabled, characters are
passed raw (without interpretation) and transparently within an rlogin
session. This allows the ZMODEM transfer to complete. See Table 18 for
ZMODEM requirements.
Table 18
ZMODEM requirements
Feature
Typeahead
TCP window size
telnet CSI ES
telnet NEW LINE FILTER
Communication Server 1000E
Setting
1024
1024
Enabled
LF or Standard
Installation and Commissioning