Test the CP PM Call Server
Procedure 21

Testing the CP PM Call Server

1
Verify that the CP PM Call Server is active.
LD 135
STAT CPU
2
Check dial-tone.
3
Verify that the CP PM Call Server is active, redundant, and single.
4
Make internal, external, and network calls.
5
Check attendant console activity.
6
Check IP Peer networking for incoming and outgoing calls.
7
Check applications (CallPilot, Symposium, and so on).
Install the software on the second CP PM Call Server
Procedure 22
Installing the software on the second CP PM Call Server
1
Attach the ELAN and TLAN cables to the CP PM faceplate connectors
between the CP PM Call Servers.
2
Complete procedures 22 through 27 for the second CP PM Call Server.
3
Each CP PM Call Server can be named: CP PM Call Server 1 and CP PM
Call Server 0.
Note: Do not install ELAN and TLAN cables at this time.
Installing software on the CS 1000E
Load program
Get the status of the CPUs
End of Procedure