Nortel 1000 Installation And Commissioning Manual page 224

Table of Contents

Advertisement

Page 224 of 466
Figure 101
Stand-alone Signaling Server configuration
CS 1000 Signaling Server Software Install Tool (sse-x.xx.xx)
=====================================================================
Please define the data networking parameters for this Standalone
Signaling Server. Note that the ELAN parameters are necessary for
management access (e.g. SNMP).
Hostname
ELAN IP
ELAN subnet mask: 255.255.255.0
ELAN gateway IP : 192.168.10.1
TLAN IP
TLAN subnet mask: 255.255.255.0
TLAN gateway IP : 192.168.20.1
NN43041-310
Standard 01.11
Installing a Signaling Server
: SS_SA
: 192.168.10.20
: 192.168.20.20
10 Enter the data networking and IP telephony parameters for the Signaling
Server, as prompted.
If this is a Leader Signaling Server, enter the parameters for the
Node, ELAN network interface, TLAN network interface, and Call
Server as required. See Figure 83 on
— If installing the Signaling Server at an office that is not a branch
office, enter the ELAN network interface IP address of the Call
Server.
— If installing the Signaling Server at a branch office, enter the
ELAN network interface IP address of the MG 1000B Core.
If this is a Follower Signaling Server, enter the Hostname of the
Leader Signaling Server. The IP telephony parameter configuration
screen appears (Figure 102 on
October 2008
page
209. For the Call Server:
page
225).

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000eCommunication server 1000Communication server 1000e

Table of Contents