4. Tighten the fastening screw M6x34 to 10 Nm (7.5 ftlb.).
5. Tighten the hose clamp on the connecting hose. Reconnect the plug on the hot film mass air flow sensor.
The plug must engage audibly!
6. Attach the connecting hose between the left turbocharger and the intake distributor. The hose must engage
audibly!
996420, 996421, 996450, 996451, 996620, 996621, 996650, 996651, 996840, 996841
Installing air cleaner
einordnung
616