20. Relieve drive belt. To do this turn the tensioning roller clockwise, hold and simultaneously remove the
drive belt.
21. Remove pulley from the hydraulic pump.
22. Remove generator.
23. Disconnect the hydraulic lines with plug−in coupling on the expansion tank.
Note
•
Wear protective gloves!
Collect emerging Pentosin!
•
Protect the line against dirt and scratches with a cap!
•
•
If hoses come into contact with Pentosin, clean them thoroughly without delay!
24. Insert tool between lines and the red unlocking ring and unlock by pulling black line to the right
and simultaneously pressing the tool against the red unlocking ring.
25. Unscrew two fastening screws (M8 x 25) with hexagon socket head bolts on the tank.
Removal
einordnung