Distribution of the oil quantity in the refrigerant circuit
Note
•
Oil removed by suction must be returned to the system!
•
Refrigerant oil removed from a previously run air−conditioning system may no longer be used
(special−category waste)!
•
After the refrigerant has been removed by suction and a component has been replaced, the oil quantity
must be determined and topped up by the quantity remaining in the removed component!
Total oil quantity
After suction removal from the system, the following quantities remain in the:
3
Condenser (2 x 20 cm
Evaporator
Fluid tank with lines
Compressor
Circulating oil quantity in the refrigerant circuit
996420, 996421, 996450, 996451, 996620, 996621, 996650, 996651, 996840, 996841
Refilling the air−conditioning system
)
einordnung
Oil quantity
195 ± 15 cm
approx. 40 cm
approx. 30 cm
approx. 30 cm
approx. 50 cm
approx. 60 cm
3
3
3
3
3
3
1072