Replacing An Mx240 Pic; Removing An Mx240 Pic - Juniper MX240 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

MX240 3D Universal Edge Router Hardware Guide

Replacing an MX240 PIC

Removing an MX240 PIC

316
Removing an MX240 PIC on page 316
1.
Installing an MX240 PIC on page 318
2.
PICs are hot-insertable and hot-removable. When you remove a PIC, the router continues
to function, although the PIC interfaces being removed no longer function.
The PICs are located in the FPCs installed in the front of the router. A PIC weighs less
than 2 lb (0.9 kg).
To remove a PIC (see
Figure 142 on page
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
1.
PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each
transceiver and cable.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
2.
ESD points on the chassis.
Use one of the following methods to take the PIC offline:
3.
Press its online/offline button. For a PIC installed in FPC3, use a narrow-ended tool
that fits inside the opening that leads to the button. Press and hold the button until
the PIC LED goes off (about 5 seconds).
Issue the following CLI command:
user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the
Label the cables connected to the PIC so that you can later reconnect each cable to
4.
the correct PIC.
Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately
5.
cover each transceiver and the end of each cable with a rubber safety cap.
WARNING:
Do not look directly into a fiber-optic transceiver or into the
ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable
connected to a transceiver emit laser light that can damage your eyes.
CAUTION:
Do not leave a fiber-optic transceiver uncovered except when
you are inserting or removing cable. The safety cap keeps the port clean
and prevents accidental exposure to laser light.
317):
CLI Explorer
Copyright © 2017, Juniper Networks, Inc.
.

Advertisement

Table of Contents
loading

Table of Contents