Figure 134: Removing An Fpc - Juniper MX240 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

MX240 3D Universal Edge Router Hardware Guide
304
CAUTION:
The weight of the FPC is concentrated in the back end. Be
prepared to accept the full weight—up to 18 lb (8.2 kg)—as you slide the
FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles,
bus bars, or edge connectors. They cannot support its weight.
Do not stack FPCs on top of one another after removal. Place each one
individually in an electrostatic bag or on its own antistatic mat on a flat,
stable surface.
If necessary, remove each installed PIC from the FPC.
10.
After you remove each PIC, immediately place it on an antistatic mat or in an
11.
electrostatic bag.
If you are not reinstalling an FPC into the emptied DPC slots within a short time, install
12.
a blank DPC panel over each slot to maintain proper airflow in the card cage.
CAUTION:
After removing an FPC from the chassis, wait at least 30
seconds before reinserting it or inserting an FPC into a different slot.

Figure 134: Removing an FPC

SC B
SC B