Installing an MX240 DC Normal Capacity Power Supply

340
Loosen the captive screws on the bottom edge of the power supply faceplate.
8.
Carefully move the power cables out of the way.
9.
Pull the power supply straight out of the chassis.
10.

Figure 153: Removing a DC Power Supply from the Router

WARNING:
Before performing DC power procedures, ensure that power is
removed from the DC circuit. To ensure that all power is off, locate the circuit
breaker on the panel board that services the DC circuit, switch the circuit
breaker to the off position, and tape the switch handle of the circuit breaker
in the off position.
To install a DC power supply (see
Ensure that the voltage across the DC power source cable leads is 0 V and that there
1.
is no chance that the cable leads might become active during installation.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
2.
ESD points on the chassis.
Switch the DC circuit breaker on the DC power supply faceplate to the off (
3.
Using both hands, slide the power supply straight into the chassis until the power
4.
supply is fully seated in the chassis slot. The power supply faceplate should be flush
with any adjacent power supply faceplate or blank installed in the power supply slot.
Tighten the captive screws on the lower edge of the power supply faceplate.
5.
Figure 105 on page
260):
Copyright © 2017, Juniper Networks, Inc.
) position.
O