Replacing An Mx240 Scb - Juniper MX240 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

Related
Documentation

Replacing an MX240 SCB

Copyright © 2017, Juniper Networks, Inc.
user@host> show chassis alarms
Alarm Time
Class Description
2011-06-01 13:37:43 EDT Minor Require a fan tray upgrade
2011-06-01 13:37:26 EDT Minor Backup RE Active
The major alarms are not displayed anymore, and the upgrade is successfully
completed.
Disable the upgrade configuration by issuing the
9.
command and then the
You can delete that command by issuing the
10.
and then the
command.
commit
Verify the SCBs before you finish by issuing the
11.
user@host> show chassis hardware
Item
Version
Part Number Serial Number Description
CB0
REV 02 750-031391 YE8505
CB1
REV 07 710-031391 YL6769
You can see that the MX240 now has the MX SCBEs.
Removing an MX240 SCB on page 356
Installing an MX240 SCB on page 261
Before replacing an SCB, read the guidelines in Operating and Positioning the MX240 SCB
Ejectors.
Removing an MX240 SCB on page 356
1.
Installing an MX240 SCB on page 357
2.
Upgrading an MX240 SCB on page 359
3.
Upgrading an MX240 SCB or SCBE to SCBE2 on page 367
4.
Chapter 27: Replacing Switch Fabric Components
set chassis state cb-upgrade off
commit
command.
delete chassis state cb-upgrade
show chassis hardware
Enhanced MX SCB
Enhanced MX SCB
command
command:
355

Advertisement

Table of Contents
loading