Juniper MX240 Hardware Manual page 371

3d universal edge router
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nuts and washers from the terminal studs.
7.
Secure each power cable lug to the terminal studs, first with the flat washer, then
8.
with the nut (see
Figure 106 on page
(2.8 Nm) of torque to each nut. Do not overtighten the nut. (Use a 7/16-in. [11 mm]
torque-controlled driver or socket wrench.)
a. Secure the positive (+) DC source power cable lug to the
b. Secure the negative (–) DC source power cable lug to the
CAUTION:
Ensure that each power cable lug seats flush against the surface
of the terminal block as you are tightening the nuts. Ensure that each nut
is properly threaded onto the terminal stud. The nut should be able to spin
freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may
result in damage to the terminal stud.
CAUTION:
The maximum torque rating of the terminal studs on the DC
power supply is 36 lb-in. (4.0 Nm). The terminal studs may be damaged
if excessive torque is applied. Use only a torque-controlled driver or socket
wrench to tighten nuts on the DC power supply terminal studs.
CAUTION:
You must ensure that power connections maintain the proper
polarity. The power source cables might be labeled
their polarity. There is no standard color coding for DC power cables. The
color coding used by the external DC power source at your site determines
the color coding for the leads on the power cables that attach to the
terminal studs on each power supply.
NOTE:
The DC power supply in
power feeds derived from feed
be powered by dedicated power feeds derived from feed
configuration provides the commonly deployed
the system.
NOTE:
For information about connecting to DC power sources, see
Power Supply Electrical Specifications for the MX240 Router" on page
Chapter 26: Replacing Power System Components
260). Apply between 23 lb-in. (2.6 Nm) and 25 lb-in.
RTN
must be powered by dedicated
PEM0
A
, and the DC power supply in
A/B
(return) terminal.
(input) terminal.
–48V
and
to indicate
(+)
(–)
PEM2
must
. This
B
feed redundancy for
"DC
143.
341