Installing An Mx240 Mpc; Figure 140: Removing An Mpc - Juniper MX240 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

Installing an MX240 MPC

Copyright © 2017, Juniper Networks, Inc.
When the MPC is out of the chassis, do not hold it by the ejector handles,
bus bars, or edge connectors. They cannot support its weight.
Do not stack MPCs on top of one another after removal. Place each one
individually in an electrostatic bag or on its own antistatic mat on a flat,
stable surface.
If necessary, remove each installed MIC from the MPC.
10.
After you remove each MIC, immediately place it on an antistatic mat or in an
11.
electrostatic bag.
If you are not reinstalling an MPC into the emptied line card slots within a short time,
12.
install a blank DPC panel over each slot to maintain proper airflow in the card cage.
CAUTION:
After removing an MPC from the chassis, wait at least 30
seconds before reinserting it or inserting an MPC into a different slot.

Figure 140: Removing an MPC

MPC
SC B
SC B
An MPC installs horizontally in the front of the router. The MPCs are hot-insertable and
hot-removable. A fully configured MPC can weigh up to 18.35 lb (8.3 kg). Be prepared to
accept its full weight.
To install an MPC (see
Figure 97 on page
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis.
Place the MPC on an antistatic mat.
2.
Chapter 25: Replacing Line Card Components
244):
313

Advertisement

Table of Contents
loading

Table of Contents