MX240 3D Universal Edge Router Hardware Guide
394
Issue the CLI
show chassis fpc
shown in the sample output, the value
that the MPC is functioning normally:
user@host> show chassis fpc
Temp
Slot State
(C)
0
Online
36
1
Online
40
2
Online
41
For more detailed output, add the
a slot number, which is optional:
user@host> show chassis fpc detail
Slot 0 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 1 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 2 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Issue the CLI
show chassis fpc pic-status
, and
, bottom to top:
1
2
user@host> show chassis fpc pic-status
Slot 0
Online
MPC Type 2 3D EQ
PIC 0
Online
1x 10GE XFP
PIC 1
Online
1x 10GE XFP
Slot 1
Online
MPC 3D 16x 10GE
PIC 0
Online
4x 10GE(LAN) SFP+
PIC 1
Online
4x 10GE(LAN) SFP+
PIC 2
Online
4x 10GE(LAN) SFP+
PIC 3
Online
4x 10GE(LAN) SFP+
Slot 2
Online
MS-DPC
command to check the status of installed MPCs. As
in the column labeled
Online
CPU Utilization (%)
Memory
Total
Interrupt
DRAM (MB) Heap
3
0
2048
5
0
2048
6
0
1024
detail
option. The following example does not specify
Online
36 degrees C / 96 degrees F
2048 MB
806 MB
2632 MB
2009-12-22 12:27:04 PST
6 days, 3 hours, 8 minutes, 41 seconds
450 Watts
Online
40 degrees C / 104 degrees F
2048 MB
1324 MB
5120 MB
2009-12-22 12:27:02 PST
6 days, 3 hours, 8 minutes, 43 seconds
440 Watts
Online
41 degrees C / 105 degrees F
1024 MB
128 MB
2048 MB
2009-12-22 12:26:48 PST
6 days, 3 hours, 8 minutes, 57 seconds
265 Watts
command. The MPC slots are numbered
indicates
State
Utilization (%)
Buffer
14
13
26
13
7
43
Copyright © 2017, Juniper Networks, Inc.
1/0
,