Table 81: Sample Power Requirements for an MX240 Router

Chassis Component
Base system
High-capacity cooling system
MPC - Slot 2 -
MPC - Slot 1
SCB 1/Slot 0
SCB 0
Total output power
Output power excluding cooling system
154
The following sample configuration shows an MX240 router with:
Two 16-port 10-Gigabit Ethernet MPCs with SFP+
Two SCBs with two (redundant) RE-1800x2 routing engines
High-capacity cooling system
NOTE:
The high-capacity cooling system satisfies cooling requirements
of MPCs, and must be used for proper cooling.
Calculate the power requirements (usage) using the values in
1.
for an MX240 Router" on page 128
Part Number
MX240BASE-AC-HIGH
FANTRAY-MX240-HC
MPC-3D-16XGE-SFPP-R-B
MPC-3D-16XGE-SFPP-R-B
SCBE2-MX with
RE-S-1800X2-8G
SCBE2-MX with
RE-S-1800X2-8G
Evaluate the power budget. In this step, we check the total output power against the
2.
maximum output power of available power supply options.
NOTE:
The power for the cooling system comes from a different tap on
the power supply, reserved for the cooling system only. The cooling system
power requirement does not need to be deducted from the output power
budget of the power supply.
as shown in
Table 72 on page
Power Requirement
40 W
85 W
440 W
440 W
185 W
90 W
185 W
90 W
1555 W
1470 W