3-6. SOLENOID POSITION ADJUSTMENT

1) Adjustment of Manual Feed Paper Pick-Up Solenoid Position

Requirement
The Paper Stoppers should be fixed perpendicularly when the Pick-Up Solenoid is ON.
Adjustment Procedure
8. Move the Pick-Up Solenoid in the direction of arrow , then slowly move it in the direction of arrow
9. Move the Pick-Up Solenoid up to the position where the Lock Lever of the Paper Stopper becomes
perpendicular (the position where the Paper Stopper is locked).
Be careful since if the Pick-Up Solenoid is moved too much, the set condition is released. If the set
condition is released, set the Pick-Up Solenoid to ON again and repeat from step 7.
10. After the adjustment has been made, tighten the two the Pick-Up Solenoid mounting screws.
Check after Adjustment
Check that the Paper Stopper is securely locked perpendicularly when the Pick-Up Solenoid is ON.
(If adjustment is insufficient, the Paper Stopper may not be locked or the set condition may not be
kept even when the Pick-Up Solenoid is ON.)
1. Remove the Right Door.
2. Remove three screws and the Multi-Bypass Unit.
3. Remove two screws and the Manual Feed Paper Pick-Up
Solenoid Assy cover.
4. Loosen two screws, slide the pivot shaft, and remove the
Multi Bypass Table.
5. Remove three screws, unplug two connectors, and remove
the Manual Feed Paper Pick-Up Solenoid Assy.
1075D154AA
6. Set the Pick-Up Solenoid to ON.
Since a keeper solenoid is used as the Pick-Up Solenoid,
the set condition is kept when the Pick-Up Solenoid is ON.
7. Loosen the two screws by which the Pick-Up Solenoid is
mounted.
1075D155AA
1075D156AB
Reference
D-76
.
1075D157AB