3-4. SENSOR ADJUSTMENT

• Adjustment of Front Upper Door Set Sensor Position

1. Open the Front Upper Door.
2. Accessing through the notch in the Right Front Cover,
loosen the screw by which the Set Sensor Assy is
mounted.
1075D128AA
3. Since the Set Sensor and the magnet catch are located on
the same mounting bracket, move them so that the Front
Upper Door is securely locked when it is closed.
4. After the Set Sensor and the magnet catch are moved,
tighten the mounting screw.
5. Check the Set Sensor is activated and deactivated and the
door locks by closing and opening the Front Upper Door.
1075D129AA
D-71