2) Cleaning of the PC Drum Charge Corona Housing

3) Cleaning and Replacement of the Grid Mesh

4) Removal of the Image Transfer/Paper Separator Coronas

Using a soft cloth dampened with alcohol, wipe clean the
corona housing.
NOTE
Use care when cleaning the housing, as it is easy to
deform.
1075D106AA
Blow all foreign matter off the Grid Mesh with a blower brush.
NOTE
If the blower brush is not effective in cleaning the Grid
Mesh, use a soft cloth dampend with alcohol to clean
serious contamination.
NOTE
Place the Grid Mesh on a flat surface and sweep the
cloth along the mesh.
Do not touch the cleaned Grid Mesh with bare hands.
1. Open the Front Lower Door.
2. Lower Lever M4 and slide out the Transport Tray Assy.
3. Remove one screw and the fixing bracket.
1155D080AC
4. Remove the Image Transfer/Paper Separator Coronas.
5. Unplug the connector of the Image Transfer/Paper
Separator Charge Wire Cleaning Motor.