2-8. FUSING UNIT

1) Removal of the Fusing Unit

2) Disassembly of the Fusing Unit and Replacement of Parts

1. Swing down the Front Lower Door.
2. Lower Lever M4 and slide out the Transport Tray Assy.
3. Remove three screws and the Fusing Front Cover.
1155D091AA
4. Unplug one connector.
1155D092AA
5. Remove one screw and the Fusing Unit.
NOTE
When the Fusing Unit has been replaced, clear the count
of Fusing Unit of PM Counter 4/4 and Waste Toner-Count
of Consumables Counter available from Tech. Rep.
mode.
1155D093AA
1. Remove the Fusing Unit.
2. Remove four screws and the Web Roller Assy.
NOTE
For the Web Roller Assy, see p. D-63.
1075D242AA
3. Remove one screw each at the front and rear and the
Upper Paper Separator Fingers Assy.
NOTE
For the Upper Paper Separator Fingers Assy, see
p. D-61.
1155D094AA
D-57