6) Removal of the Lift-Up Motor (Metric areas only)

1. Remove the Right Rear Cover and Rear Cover.
2. Unplug the connectors from Toner Replenishing Motor
Control Board and Drawer S/P Board and remove the
harness from the wiring saddle.
3. Remove four screws and the mounting brackets for the
Toner Replenishing Motor Control Board and the Drawer
S/P Board.
1155D008AA
4. Remove the Toner Collecting Bottle. Remove two screws,
unplug one connector, and remove the metal plate.
5. Remove four screws to free the Vertical Transport Motor
Assy.
1075D018AB
6. Remove five screws. Slightly raising the Paper Take-Up
Drive Assy, remove it together with the Vertical Transport
Motor Assy.
1075D019AB
7. Unplug two connectors, remove two screws and the Lift-Up
Motor Assy.
1075D020AA
8. Remove the C-clip and the Lift-Up Motor.
1075D204AA
D-16