C0600 Scanner Motor M31 Malfunction; C0602 Cable Unwound; C0650 Shome Signal Error; C0910 2Nd Drawer Lift-Up Failure - Minolta Di 620 Manual

Hide thumbs Also See for Di 620:
Table of Contents

Advertisement

C06∗∗ Optical Section malfunctions
Code
Description

C0600 Scanner Motor M31 malfunction

C0602 Cable unwound

C0650 SHOME signal error

C09∗∗ Paper Take-Up Section malfunctions
Code
Description

C0910 2nd Drawer Lift-Up failure

C0911
2nd Drawer lock release failure
<Inch
Areas
Only>
Detection Timing
Encoder pulses are not input to SCP Board PWB-IC at
50-msec. intervals while M31 is turning.
Scanner Reference Position Sensor PC55 is not blocked
([H]) despite the fact that the M31 encoder pulse count
represents that the Scanner is at a position 5 mm or
more to the rear (to the right as viewed from the front)
from its home position.
Scanner Reference Position Sensor PC55 is blocked
([L]) when the M31 encoder pulse count is a value that is
equivalent to the Scanner at a position 12 mm before its
home position.
Detection Timing
<Metric Areas>
• 2nd Drawer Paper Lift-Up Sensor PC41 is not blocked
([L]) even after the lapse of 5 sec. after 2nd Drawer
Lift-Up Motor M25 has started turning.
• PC41 is not blocked ([L]) even when 2nd Drawer Lift-
Up Motor Pulse Sensor PC26 detects 150 HIGH-going
and LOW-going edges after M25 has started turning.
<Inch Areas>
• 2nd Drawer Paper Lift-Up Sensor PC41 is not blocked
([L]) even after the lapse of 5 sec. after 2nd Drawer
Lift-Up Motor M25 has started turning forward (for
upward motion).
• PC41 is not blocked ([L]) even when 2nd Drawer Lift-
Up Motor Pulse Sensor PC26 detects 150 HIGH-going
and LOW-going edges after M25 has started turning
forward (for upward motion).
• 2nd Drawer Lower Position Sensor PC19 is not
blocked ([L]) even after the lapse of 5 sec. after M25
has started turning backward (for downward motion).
• PC19 is not blocked ([L]) even when PC26 detects 150
HIGH-going and LOW-going edges after M25 has
started turning backward (for downward motion).
• PC19 is not unblocked ([H]) even after the lapse of 1.5
sec. after it has been blocked ([L]) while M25 is turning
backward (for downward motion).
• PC19 is not blocked ([L]) even after the lapse of 5 sec.
while M25 is turning forward (for upward motion) after
the drawer has been unlocked.
• PC19 is not unblocked ([H]) even after the lapse of 5
sec. after it has been blocked ([L]) while M25 is turning
forward (for upward motion) after the drawer has been
unlocked.
The 2nd Drawer is not pushed out even after the lapse
of 10 sec. after PC19 has been unblocked ([H]) while
M25 is turning backward (for downward motion).