5) Adjustment of the Duplex Unit Turnover Exit Solenoid Position
Requirement
The gap between the guide fingers and guide plate should be 4 +
Solenoid is ON.
Adjustment Procedure
4. Move the Turnover Exit Solenoid Assy so that the gap between the guide fingers and guide plate is
1
4 +
mm when the Turnover Exit Solenoid is ON.
0
5. After the adjustment is completed, tighten the two mounting screws.
1. Remove the Left Lower Door.
2. Remove four screws and the mounting bracket.
1155D141AA
3. Loosen one screw by which the Turnover Exit Solenoid
Assy is mounted.
1155D139AA
D-80
1
mm when the Turnover Exit
0
1155D140AD