3) Adjustment of the Exit/Duplex Switching Solenoid Position
Requirement
The stopper of the Exit/Duplex Switching Plate should be in contact with the guide plate when the
Switching Solenoid is energized.
Adjustment Procedure
3. Adjust the position of the Switching Solenoid Assy so that the stopper of the Exit/Duplex Switching
Plate comes in contact with the guide plate when the Switching Solenoid is energized.
4. After the adjustment is completed, tighten the Switching Solenoid Assy mounting screw.
1. Remove the Left Upper Door.
2. Loosen the screw by which the Switching Solenoid Assy is
mounted.
1155D142AA
D-78
1155D143AE