Rom Version - Minolta Di 620 Manual

Hide thumbs Also See for Di 620:
Table of Contents

Advertisement

Touch Panel Display
I.R. & EDH Check
EDH I/O Check
EDH Paper Passage
1155SBS050407A

7) ROM Version

Touch Panel Display
ROM Version
Tech. Rep. Mode
Checks each sensor used in the EDH and shows its status with either 0 or
1.
<Procedure>
1. With the EDH I/O check screen on the Touch Panel, directly activate or
deactivate each sensor.
2. The copier shows either 1 or 0 on a realtime basis.
Makes a paper passage check through the EDH in its different operating
modes.
<Procedure>
1. Touch the desired sub-function key.
2. Press the Start key to start the check sequence.
Note: The copier automatically stops as soon as it completes the check
sequence. The Stop key may, however, be pressed to halt the
sequence.
Tech. Rep. Mode
Displays the version of the current ROM.
Note: No versions are displayed if the system is not mounted with a ROM.
<Procedure>
1. Touch [ROM version] to open the ROM Version screen.
2. The screen shows the ROM version.
Display
MSC
IC71B
Massage
IC21B
ECC
IC2/3W
IR
IC26IB
Printer
IC2A
Finisher
IC2
Data Controller
IC2
S-44
I.R. & EDH Check
Setting
ROM Version
Setting
PWB-B
PWB-B
PWB-W
PWB-IB
PWB-A
FN-3 PWB-A
D-102 PWB
Description