C0BC∗ Paper folding malfunctions
Code
Description
C0BC0 1st Crease Stopper Motor M12's
failure to turn
C0BC1 1st Crease Stopper Motor M12's
failure to turn
C0BC2 Paper Crease Motor M11's failure
to turn
C0BC3 Paper Crease Motor M11 turning at
abnormal timing
C0BF∗ Control system malfunctions
Code
Description
C0BF0 Control failure
C0E∗∗ Erase lamp malfunctions
Code
Description
C0E00 Main Erase Lamp LA1's failure to
turn ON
C0F∗∗ Sensor malfunctions
Code
Description
C0F24 AIDC Sensor UN6 contamination
correction failure

C0F32 ATDC Sensor UN4 failure

C0F33 Abnormally low T/C as detected by
ATDC Sensor UN4
C0F34 T/C recovery failure as detected by
ATDC Sensor UN4
Detection Timing
∗See the option service manual.
Detection Timing
∗See the option service manual.
Detection Timing
• The LA1 Malfunction signal remains LOW for a contin-
uous 1-sec. period while LA1 remains OFF.
• The LA1 Malfunction signal remains HIGH for a con-
tinuous 1-sec. period while LA1 remains ON.
Detection Timing
The UN6 output voltage does not fall within the range of
0.9V to 1.1V even after the contamination correction and
variation adjustment.
• The UN4 output voltage remains 0.2V or less, or 4.5V
or more, for a continuous 3-sec. period after Develop-
ing Unit Drive Motor M1 has been energized.
• The UN4 output voltage does not fall within the range
of 2.45V to 2.55V during an F8 operation.
A T/C of 2.5% or less (ATDC Sensor output being 3.2V
or more) is detected.
A toner replenishing sequence does not bring T/C to a
normal level within 3 min. after a T/C of 3% or less
(ATDC Sensor output being 2.86V or more) has been
detected.