10) Cleaning of the AIDC Sensor
11) Replacement of the Toner Antispill Seal
6. When reinstalling the PC Drum Paper Separator Fingers,
be sure to rehook the torsion spring correctly as shown.
After reinstallation, check that the fingers move smoothly.
1075D094AA
7. Move the separator fingers and the pressure lever laterally
to ensure that they move smoothly.
NOTE
Whenever the PC Drum Paper Separator Fingers have
been removed and reinstalled, be sure to adjust the
position of the PC Drum Paper Separator Fingers. For
details, see p. D-79.
1155D217AA
1. Slide out the PC Unit.
2. Remove the PC Drum.
3. Using a soft cloth dampened with alcohol, wipe clean the
AIDC Sensor.
1155D122AA
1. Remove the PC Drum.
2. Remove the Cleaning Unit.
3. Turn over the Cleaning Unit, remove four screws, unplug
one connector, and remove the PC Drum Paper Separator
Fingers Assy.
NOTE
One of the screws is provided with a collar. Be careful not
to lose it.
1161D031AA
4. Remove two screws shown.
5. Remove one screw and the Toner Antispill Seal and
replace the seal with a new one.
1155D071AA
D-44