15) Replacement of the Toner Collecting Bottle

Image Transfer/Paper Separator Coronas
1. Slide out the Transport Tray Assy.
2. Remove four screws and the Suction Deck.
1155D021AB
3. Remove four screws and Suction Fan Assy.
1155D128AA
4. Pull out the Ozone Filter and replace it.
1155D129AA
5. Remove the Rear Cover.
6. Pull out the Ozone Filter and replace it.
1155D130AA
1. Remove the Rear Cover.
2. Remove the Toner Collecting Bottle and replace it.
NOTE
When the Toner Collecting Bottle has been replaced,
clear the "Toner Collect" count of "Consumable" available
from "Counter" under the Tech. Rep. mode.