5) Replacement of the Image Transfer/Paper Separator Corona Wires and
Wire Cleaners

6) Cleaning of the Image Transfer/Paper Separator Coronas Housing

7) Cleaning of the Pre-Image Transfer Guide Plate

1. Remove the Image Transfer/Paper Separator Coronas.
2. Remove the holder covers at the front and rear and four
paper guides.
1155D082AA
3. Extend the corona wire spring and remove the corona wire
and wire cleaner.
1155D083AA
Using a soft cloth dampened with alcohol, wipe the housing
clean of dirt.
1155D084AA
Using a soft cloth dampened with alcohol, wipe the guide
plate clean of dirt.
NOTES
1) Use care not to peel off the seal at the center of the
guide plate.
2) Be also careful not to remove the plastic parts on both
ends of the guide plate.
1155D085AA
D-50