8) Cleaning of the Toner Antispill Seal, AIDC Sensor, and PC Drum Paper
Separator Fingers

9) Disassembly of the PC Drum Paper Separator Fingers Assy

5. Remove the PC Drum Paper Separator Fingers and AIDC Sensor as illustrated below.
NOTE
During removal and reinstallation of the PC Drum Paper Separator Fingers, use care not to
damage the tips of the fingers (scratches, bend, etc.).
Be also careful not to hurt yourself with the tips of the fingers.
1. Remove the PC Drum.
2. Using a brush or soft cloth, clean the Toner Antispill Seal,
AIDC Sensor, and PC Drum Paper Separator Fingers.
1075D090AA
1. Remove the PC Drum.
2. Unplug one connector and remove the Cleaning Unit.
3. Turn over the Cleaning Unit, remove four screws, unplug
one connector, and remove the PC Drum Paper Separator
Fingers Assy.
NOTE
One of the screws is provided with a collar. Be careful not
to lose it.
1161D031AA
4. Remove two screws and the PC Drum Paper Separator
Fingers mounting bracket.
1075D092AA
D-43
1075D093AB