3) Cleaning and Replacement of the Upper Paper Separator Fingers

4) Replacement of the Lower Paper Separator Fingers

5) Cleaning and Replacement of the Pre-Fusing Guide Plate
24. Remove the Lower Fusing Roller and bearings.
NOTE
When the Lower Fusing Roller has been removed, clear
the count of Fusing Roller of PM Counter 4/4 available
from Tech. Rep. mode.
1075D256AA
1. Open the Upper Paper Separator Fingers Assy.
2. Using a soft cloth dampened with silicone oil, wipe clean
the Upper Paper Separator Fingers.
NOTE
If the fingers are seriously contaminated, first use a soft
cloth dampened with alcohol, then apply silicone oil to
the fingers.
Replacement
1. Remove the Upper Paper Separator Fingers Assy.
2. Unhook the finger springs, remove the E-ring, and slide out
the fixing shaft to replace the Upper Paper Separator
Fingers.
1155D104AA
1. Remove the Fusing Unit and loosen the roller pressure
springs at the front and rear.
2. Remove two screws and swing up the Upper Fusing Unit.
3. Unhook the finger springs, remove the rubber stopper, and
slide out the fixing shaft to replace the Lower Paper
Separator Fingers.
1155D106AA
1. Open the Front Lower Door.
2. Lower Lever M4 and slide out the Transport Tray Assy.
3. Using a soft cloth dampened with alcohol, wipe clean the
Pre-Fusing Guide Plate.
NOTE
For replacement of the Pre-Fusing Guide Plate, see p. D-
60.
1155D107AA