Replacement Of The Ozone Filters - Minolta Di 620 Manual

Hide thumbs Also See for Di 620:
Table of Contents

Advertisement

13) Replacement of the PC Ground Plat

14) Replacement of the Ozone Filters

1. Remove the Rear Cover.
2. Remove three screws and the Flywheel.
1155D116AA
3. Remove one screw and the PC Ground Plate. Replace the
PC Ground Plate.
1155D075AB
PC Drum Charge Corona
1. Slide out the PC Unit.
2. Pull out the Ozone Filter and replace it.
1155D076AB
3. Remove the Rear Cover.
4. Peel off the filter and remove two screws and the Toner
Suction Fan Assy.
1155D126AA
5. Pull out the Ozone Filter and replace it.
NOTE
When mounting the Ozone Filter, use care not to allow
the films on both ends of the filter to be in contact with
the fan.
1155D127AA
D-46